{"id":45,"date":"2026-01-09T12:39:14","date_gmt":"2026-01-09T12:39:14","guid":{"rendered":"http:\/\/tdc4isac.org\/?p=45"},"modified":"2026-01-09T12:41:06","modified_gmt":"2026-01-09T12:41:06","slug":"high-speed-signal-digitizer-based-on-reference-waveform-crossings-and-time-to-digital-conversion","status":"publish","type":"post","link":"http:\/\/tdc4isac.org\/index.php\/2026\/01\/09\/high-speed-signal-digitizer-based-on-reference-waveform-crossings-and-time-to-digital-conversion\/","title":{"rendered":"High-Speed Signal Digitizer Based on Reference Waveform Crossings and Time-to-Digital Conversion"},"content":{"rendered":"\n<p>Aboltins, A.; Migla, S.; Tihomorskis, N.; Ratners, J.; Barkans, R.; Kurtenoks, V. High-Speed Signal Digitizer Based on Reference Waveform Crossings and Time-to-Digital Conversion. <em>Electronics <\/em><strong>2026<\/strong>, 15, 153. https:\/\/doi.org\/10.3390\/electronics15010153<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"322\" src=\"http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-142828-1024x322.png\" alt=\"\" class=\"wp-image-46\" srcset=\"http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-142828-1024x322.png 1024w, http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-142828-300x94.png 300w, http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-142828-768x242.png 768w, http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-142828-1536x483.png 1536w, http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-142828.png 1574w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Event-driven ADC using multiple thresholds.<\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"495\" src=\"http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-143022-1024x495.png\" alt=\"\" class=\"wp-image-47\" srcset=\"http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-143022-1024x495.png 1024w, http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-143022-300x145.png 300w, http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-143022-768x371.png 768w, http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-143022.png 1463w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">MSO captured output waveforms: <strong>(a)<\/strong> test waveform (blue), sampling waveform (red), and <strong>(b)<\/strong> level detector rising (green) and falling (purple) edge.<\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"505\" src=\"http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-143216-1024x505.png\" alt=\"\" class=\"wp-image-48\" srcset=\"http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-143216-1024x505.png 1024w, http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-143216-300x148.png 300w, http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-143216-768x379.png 768w, http:\/\/tdc4isac.org\/wp-content\/uploads\/2026\/01\/Screenshot-2026-01-09-143216.png 1360w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Table. Damped sine test signal sampled by triangle and sawtooth sampling signals at different frequencies <em>f<\/em>. The first 200 time tags from both rising and falling edges are visualized.<\/figcaption><\/figure>\n<\/div>\n\n\n<p>Supplementary files are available at the <a href=\"https:\/\/www.mdpi.com\/2079-9292\/15\/1\/153\">Article&#8217;s page<\/a>.<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Aboltins, A.; Migla, S.; Tihomorskis, N.; Ratners, J.; Barkans, R.; Kurtenoks, V. High-Speed Signal Digitizer Based on Reference Waveform Crossings and Time-to-Digital Conversion. Electronics 2026, 15, 153. https:\/\/doi.org\/10.3390\/electronics15010153 Supplementary files are available at the Article&#8217;s page.<\/p>\n","protected":false},"author":1,"featured_media":49,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[24,25],"tags":[14,21,11,12,17,13,19,23,22,18,16,15,20],"class_list":["post-45","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-article","category-research","tag-asynchronous-sampling","tag-dynamic-threshold","tag-event-based-sampling","tag-level-crossing-adc","tag-nonuniform-sampling","tag-reference-waveform-crossings","tag-rf-signal-acquisition","tag-signal-reconstruction-from-time-tags","tag-slope-dependent-error","tag-stroboscopic-sampling","tag-time-tagging","tag-time-to-digital-converter","tag-uwb-radar"],"_links":{"self":[{"href":"http:\/\/tdc4isac.org\/index.php\/wp-json\/wp\/v2\/posts\/45","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/tdc4isac.org\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/tdc4isac.org\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/tdc4isac.org\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/tdc4isac.org\/index.php\/wp-json\/wp\/v2\/comments?post=45"}],"version-history":[{"count":1,"href":"http:\/\/tdc4isac.org\/index.php\/wp-json\/wp\/v2\/posts\/45\/revisions"}],"predecessor-version":[{"id":50,"href":"http:\/\/tdc4isac.org\/index.php\/wp-json\/wp\/v2\/posts\/45\/revisions\/50"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/tdc4isac.org\/index.php\/wp-json\/wp\/v2\/media\/49"}],"wp:attachment":[{"href":"http:\/\/tdc4isac.org\/index.php\/wp-json\/wp\/v2\/media?parent=45"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/tdc4isac.org\/index.php\/wp-json\/wp\/v2\/categories?post=45"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/tdc4isac.org\/index.php\/wp-json\/wp\/v2\/tags?post=45"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}